Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Acta ortop. bras ; 26(2): 91-93, Mar.-Apr. 2018. tab
Article in English | LILACS | ID: biblio-949728

ABSTRACT

ABSTRACT Objective: To define a profile of the muscle groups affected by patellofemoral pain syndrome (PFPS) to determine a pattern of functional weaknesses around the knee. Methods: Sixty-three female patients were randomly selected, and 17 included in this study, receiving a clinical evaluation with pre-established protocol which evaluated the quadriceps, abductors, range of motion in the internal rotators and ankle dorsiflexors, pelvic tilt, and dynamic valgus. Results: Losses were seen in abductor strength and ankle dorsiflexor range of motion in comparison with the contralateral limb (0.031 and 0.040, respectively). There was a loss of quadriceps strength and decreased amplitude of internal hip rotation when compared to the Kujala score (0.032 and 0.002, respectively). Dynamic valgus and pelvic fall were greater in comparison with the Kujala score (0.668 and 0.567, respectively). Conclusion: Clinical evaluation showed deficits in the quadriceps and abductor muscle groups, as well as decreased range of motion in the internal hip rotators and ankle dorsiflexors and increased dynamic valgus and pelvic drop. Level of Evidence IV; Case series.


RESUMO Objetivo: Definir o perfil de acometimento de grupos musculares envolvidos na síndrome de dor patelofemoral (SDPF) a fim de determinar um padrão de fraqueza funcional em torno do joelho. Métodos: Foram selecionados randomicamente 63 pacientes do sexo feminino, dos quais 17 foram incluídos no trabalho e submetidos a uma avaliação clínica com protocolo preestabelecido que avaliou quadríceps, abdutores, amplitude de movimento de rotadores internos e dorsiflexores de tornozelo, além de inclinação pélvica e valgo dinâmico. Resultados: Houve déficit de força de abdutores e diminuição de amplitude do movimento de dorsiflexores de tornozelo em comparação com o membro contralateral (0,031; 0,040, respectivamente). Houve déficit de força de quadríceps e diminuição de amplitude de rotação interna do quadril quando em comparação com o escore de Kujala (0,032; 0,002, respectivamente). Verificou-se aumento do valgo dinâmico e queda pélvica com relação ao escore de Kujala (0,668; 0,567, respectivamente). Conclusões: Após avaliação clínica dos pacientes incluídos, observaram-se déficits dos seguintes grupos musculares: quadríceps e abdutores, além da diminuição da amplitude de movimento de rotadores internos do quadril e dorsiflexores de tornozelo; por fim, foram identificados aumento do valgo dinâmico e queda pélvica. Nível de Evidência IV; Série de casos.

2.
Coluna/Columna ; 15(4): 283-286, Oct.-Dec. 2016. tab, graf
Article in English | LILACS | ID: biblio-828619

ABSTRACT

ABSTRACT Objective: To define whether the electroneurophysiological stimulation would be a safe method for reducing injuries in nerve roots during surgery of lumbar spine arthrodesis, as well as verify whether there is a direct correlation between the intraoperative impedance values and the distance from the medial cortical pedicle screw. Methods: Randomized retrospective multicenter study of 10 patients who underwent arthrodesis of lumbar spine after conservative treatment failure, with a total of 50 pedicle screws instrumented. Reliable and safe impedance values were measured in order to reduce the risk of injury to nerve roots in the perioperative period, and these values were compared with the distance between the screw and the medial cortical of the pedicle by CT scan, measured in the immediate post-operative period. Results: There is no direct correlation between the intraoperative impedance values and the distance from the screw to the medial cortical of the pedicle. Conclusion: The electroneurostimulation proved to be a reliable quantitative method to reduce the risk of injury to nerve roots during surgery of lumbar spine arthrodesis when the measured values are greater than 10mA.


RESUMO Objetivo: Definir se a estimulação eletroneurofisiológica seria um método seguro para redução de lesões em raízes nervosas no intraoperatório de artrodese de coluna lombar, bem como verificar se há correlação direta entre os valores de impedância transoperatória e a distância do parafuso e a cortical medial do pedículo. Métodos: Estudo retrospectivo, multicêntrico com seleção randômica consecutiva de 10 pacientes que realizaram artrodese de coluna lombossacra após falha de tratamento conservador, com um total de 50 parafusos pediculares instrumentados. Os valores confiáveis e seguros de impedância para diminuir os riscos de lesão em raízes nervosas foram aferidos no período perioperatório, sendo esses valores comparados com os da distância entre o parafuso e a cortical medial do pedículo na tomografia computadorizada, aferida no pós-operatório imediato. Resultados: Não há correlação direta entre os valores de impedância transoperatória e a distância do parafuso até a cortical medial do pedículo. Conclusão: A eletroneuroestimulação mostrou ser um método quantitativo seguro para diminuir os riscos de lesões em raízes nervosas no intraoperatório de artrodese de coluna lombar quando os valores aferidos são maiores que 10mA.


RESUMEN Objetivo: Definir si la estimulación electroneurofisiológica sería un método seguro para reducir las lesiones en las raíces nerviosas durante la cirugía de artrodesis de columna lumbar, así como verificar si hay correlación directa entre los valores de impedancia perioperatoria y la distancia entre tornillo y la cortical medial del pedículo. Métodos: Estudio retrospectivo, multicéntrico, con selección aleatoria consecutiva de 10 pacientes que fueron sometidos a la artrodesis de columna lumbosacra después de falla del tratamiento conservador, con un total de 50 tornillos pediculares instrumentados. Valores fiables y seguros de impedancia para reducir el riesgo de lesiones a las raíces nerviosas se midieron en el periodo perioperatorio, y estos valores se compararon con la distancia entre el tornillo y la cortical medial del pedículo en la tomografía computarizada, medida en el período postoperatorio inmediato. Resultados: No existe una correlación directa entre los valores de impedancia perioperatoria y la distancia desde el tornillo hasta la cortical medial del pedículo. Conclusión: La electroneuroestimulación mostró ser un método cuantitativo fiable para reducir el riesgo de lesiones a raíces nerviosas durante la cirugía de artrodesis de columna lumbar cuando los valores medidos son mayores que 10mA.


Subject(s)
Humans , Lumbar Vertebrae , Arthrodesis , Electric Impedance , Electric Stimulation , Spinal Nerve Roots
SELECTION OF CITATIONS
SEARCH DETAIL